Wood Aircraft Structures: Species, Defects, Inspection and Repair

Spruce spars, plywood skins and resorcinol glue lines still fly on many older aircraft. This guide sets out how to recognize aircraft wood and its defects, how to find moisture, decay, bond failures and compression failures, and the spar, rib and skin repairs the public documents describe, with their slopes and limits. The aircraft manufacturer's data comes first (AC 43.13-1B par. 1-36).

View PDF

1Identification

Where to buy

Numbers at a glance

ItemValue, in (mm)Source
Grain slope, maximum (all species of Table 1-1)1 in 15AC Table 1-1 col. 3; H Fig. 6-10
Hard knot, sound, center third of the beam3/8 in (9.5) max; over 1/4 in (6.4) with cautionAC Table 1-1 note 1c
Distance between 3/8 in knots or other defects20 in (508) minAC Table 1-1 note 1c(3)
Pitch pocket, center of the beam1-1/2 × 1/8 × 1/8 in (38 × 3.2 × 3.2) max, 14 in (356) apart in one ringAC Table 1-1 note 1e
Moisture content at inspection8 to 16 %, preferably 10 to 12 %AC 1-29 g
Moisture that sustains fungus20 % or moreAC 1-28 a, 1-29 g; H
Moisture before bonding6 to 8 % in arid regions, 10 to 12 % elsewhereAC 1-44 b
Repair stock from another climate, seasoning2 weeks min, in the same storage area as the partAC 1-44 b
Clamping pressure, resorcinol (typical)125 to 150 psi (0.86 to 1.03 MPa) softwood; 150 to 200 psi (1.03 to 1.38 MPa) hardwoodAC 1-10 b
Glue line, close-contact adhesive0.005 in (0.13) maxH, Glues
Bonding temperatureAbove 70 °F (21 °C); the adhesive's minimum governsH, Glues; AC 1-9
Nail strips: pitch, row spacing, stagger, penetration1 in (25) apart, rows 1/2 in (13), no nail over 3/4 in (19) from the nearest, 3/8 in (9.5) into the lower memberAC 1-11 c
Clamping block thickness2 × the thinner member, minAC 1-11 e
Scarf slope, plywood skin1 in 12 at the steepestAC 1-51 c; H, Scarf Patch
Scarf slope, stressed solid member (spar)Not steeper than 1 in 15H, scarf joints, Fig. 6-18
Reinforcement plate endsFeathered at 5 : 1AC Figs. 1-5 to 1-7; H Fig. 6-23
Spacing between splices, or splice and plate3 × the longer splice, minAC 1-40
Drain holes in a repaired portionSame as the originals, usually 1/4 in (6.4)AC 1-37
Heated bending form for plywood300 °F (149 °C) max surfaceAC 1-49 b

AC = AC 43.13-1B; H = FAA-H-8083-31B chapter 6. The manufacturer's data governs where it gives a value.

Species and permitted substitutes

SpeciesStrength against spruceGrain slopeAs a substitute for spruce
Spruce: Sitka (P. sitchensis), red, white100 % (the standard)1 in 15Excellent for all uses
Douglas firExceeds spruce1 in 15Same or slightly reduced sizes if the reduction is substantiated; splits and splinters; avoid large solid pieces (hard to inspect)
Noble firSlightly exceeds, but 8 % deficient in shear1 in 15Direct substitute in the same sizes if shear is not critical
Western hemlockSlightly exceeds1 in 15Direct substitute; upland growth better than lowland
Northern white pine85 to 96 %1 in 15Only with larger sizes to make up the strength
Port Orford white cedarExceeds spruce1 in 15Same or slightly reduced sizes if substantiated; gluing difficult
Yellow poplarSlightly less, except in compression and shear1 in 15Not a direct substitute without accounting for the lower strength

AC 43.13-1B Table 1-1; FAA-H-8083-31B Fig. 6-10. Use the original species whenever possible (AC 1-2 b). Modified woods and non-wood products need the airframe manufacturer's or the FAA's approval for a substitute. The Handbook asks for traceability to MIL-S-6073 (solid spruce) and MIL-P-6070B (plywood) on certificated aircraft (H, Suitable Wood).

Adhesives: what AC 43.13-1B says about each

AdhesiveStatusWhat to knowSource
Resorcinol-formaldehyde (two parts, resin and hardener)ALLOWEDThe only adhesive the AC names as recommended and approved for wood structure (Fed. Spec. MMM-A-181D, MIL-A-22397). Thin, uniform bond line and correct pressure are critical; full strength not relied on below 70 °F (21 °C)AC 1-4 b(4); H, Glues
Epoxy (two parts)ONLY WITH APPROVALAcceptable when it meets par. 1-4 a (aircraft manual, Mil Spec, AMS or TSO) and is compatible. Less sensitive to fit and pressure, but durability with heat or moisture is inadequate in many. Never change the mix ratioAC 1-4 a, 1-4 b(6)
CaseinCHECKDeteriorates with moisture and temperature; inferior to modern adhesives. Scrape off every trace before bonding with another type: residual alkalinity can stop the new adhesive curingAC 1-4 b(1)
Plastic resin (urea-formaldehyde)NOT ALLOWEDObsolete for all repairs: deteriorates faster than wood in hot, moist service and under swell-shrink cycles. Any proposed use goes to the FAA firstAC 1-4 b(3)
Phenol-formaldehyde (hot pressed)NOT ALLOWEDUsed to make aircraft plywood; cured under heat and pressure, not practical for structural repairAC 1-4 b(5)

Pot life, open and closed assembly time, temperature and pressure: the adhesive maker's instructions (AC 1-8, 1-9). If an assembly time is exceeded, do not continue the bond (AC 1-8 note).

2Allowable damage

Defects in the stock: accept or reject

DefectHow to recognize itDecisionSource
Cross grain (spiral, diagonal)Check all four faces. Slope is the number of units in which the grain deviates one unit; a scribe drawn along the grain or a drop of free-flowing ink shows the directionALLOWED to 1 in 15; steeper: rejectAC Table 1-1 note 1a, 2a; ANC-19 sec. 2.302
Wavy, curly, interlocked grainLocal irregularities in the grain lineALLOWED if within the cross-grain limitAC note 1b, 2b
Hard knotsSound, hard knotsALLOWED to 3/8 in (9.5 mm) in the center third, 20 in (508 mm) from another defect, not on I-beam projections or flange edges; otherwise rejectAC note 1c, 2c
Pin knot clustersSmall clusters of tiny knotsALLOWED if the effect on grain is smallAC note 1d, 2d
Spike knotsKnot running through the depth of a beam, across the rings; mostly in quarter-sawn stockNOT ALLOWEDAC note 2e
Pitch pocketsResin-filled openings along a ringALLOWED within the note 1e size and spacing; otherwise rejectAC note 1e, 2f
Mineral streaksDark streaksALLOWED only if close inspection shows no decayAC note 1f, 2g
Checks, shakes, splitsCheck: longitudinal crack across the rings. Shake: between two rings. Split: from induced stressNOT ALLOWEDAC note 2h; ANC-19 sec. 2.303
Compression woodHigh specific gravity, excessive summerwood, little color contrast between spring and summer wood; formed on the lower side of leaning softwood trees, wide rings; in a thin section the summerwood looks opaque against a bright lightNOT ALLOWED; in doubt, reject or toughness testAC note 2i; ANC-19 sec. 2.306
Compression failuresBuckled fibers: streaks roughly at right angles to the grain, from pronounced to hairlineNOT ALLOWED if obvious; in doubt, microscope or toughness testAC note 2j
Decay (rot, dote, red heart, purple heart)Stains and discoloration that are not harmlessNOT ALLOWED in any pieceAC note 2k; H, Defects Not Permitted

Selecting and approving wood stock is a specialized skill (AC 1-2 a); the AC refers to ANC-19 for aircraft-quality wood.

Damage in service and where it hides

Five failure modes. Decay (fungi need about 20 percent moisture or more); splitting, typically where a plywood doubler restrains a spruce member that shrinks as it dries; bond failure, from poor fabrication or long exposure to moisture; finish failure, the last barrier against water; and mechanical damage, including wood crushed under an overtightened fitting (AC 43.13-1B par. 1-28).

Where to look first. Spars at the ends of the plywood reinforcement plates at the lift-strut fittings, for compression and longitudinal cracks; rib attach points either side of the strut fittings; all metal fittings on wood, for looseness, corrosion and cracks; nose ribs and leading-edge skin ahead of the jury strut; exposed end grain, spar butts above all, which check in arid climates. Triple-check spars and spar-to-fuselage fittings after a wingtip strike or a ground loop (AC 1-29 f(2); H Fig. 6-8).

Signs under the covering. Swelling or warp; dark gray stains along the grain; fittings sunk into the wood; corroded screws or bolts, which mean moisture and probably decay next to them; splits in fabric over plywood, which call for removing the fabric and inspecting the plywood (AC 1-29 a, f(1), f(2)(j); H, External & Internal Inspection). A plate whose ends are not feathered is a stress riser where the primary structure can be expected to fail (AC 1-29 a).

Inspection methods and what each one finds

MethodSound resultBad sign, and next stepSource
Moisture meter (probe through the skin if needed)8 to 16 %, best 10 to 12 % (AC); 8 to 12 % (H)20 % or more: fungus likely; dry the aircraft and inspect for decayAC 1-29 g; H, Inspection of Wood Structures
Tapping with a light plastic hammer or screwdriver handleSharp, solid reportHollow, soft: go on to probingAC 1-29 b
Probing with a sharp toolSolid and firmSoft, mushy: assume rot; disassembleAC 1-29 c
Prying at bond joints; feeler gauge at glue linesNo relative movement, no separationMovement: bond failure; disassembleAC 1-29 d; H Fig. 6-6
Smell, when the panels come offNo odorMusty or moldy: moisture and fungusAC 1-29 e
Light at a low angle, parallel with the grainStraight grainGrain waviness: possible compression failureAC 1-29 f(2)(m); H, Inspection of Wood Structures
Borescope or inspection holes (aft face of front spar, fore face of rear spar)No cracksCompression or longitudinal cracks, loose rib nails: investigateAC 1-29 f(2)(m)
Removing a few screws or boltsBright fastenersCorrosion: moisture, probable decay nearbyAC 1-29 f(2)(j); H
Sample joint from the same batch, broken after cureWood fibers on both faces; at least 75 % wood failure (H)Failure in or along the bond line: poor bondingAC 1-29 h; H, Testing Glued Joints

Keep the aircraft in a dry, ventilated hangar with all covers off as long as possible before the final inspection (AC 1-29). The manufacturer's inspection data is followed in all cases.

What may stay, what is repaired, what is replaced

FindingDecisionSource
Decay, any amount or formNOT ALLOWED: repair or replace the woodAC 1-28 a
Compression failure in a sparNOT ALLOWED to stay; can lead to wing failure in flight; the manufacturer's data decides splice or replacementAC 1-29 f(2)(k); H
Longitudinal crack in a solid or laminated spar (not a box spar)ONLY WITH APPROVAL: bonded spruce or plywood plates both sides, well past the crack (Fig. 1-10). No procedure fits every model: the manufacturer, or the FAA when not per the manufacturer or the ACAC 1-44, 1-44 b
Elongated bolt holes, cracks near bolt holesSplice in a new section or replace the spar. Minimal damage at non-critical fittings: repair ONLY WITH APPROVAL (manufacturer or FAA)AC 1-45
Bond line moves or opensNOT ALLOWED: disassemble, clean and rebondAC 1-29 d
Slight bulging between panels of single plywood coveringCHECK: may be permissible if wood and glue are sound; check the attachment to the structureH, External & Internal Inspection
Hole in plywood skin up to 1 in (25 mm), 1 in from any frame, not on a leading edge or the fuselage frontALLOWED: doped fabric patchAC 1-52
Plywood stressed covering damaged over 6 in (152 mm) in any directionRepair is a MAJOR REPAIR: FAA Form 33714 CFR 43 App. A (b)(1)(xxii)
Crack length, decay depth or damage size that may remain—: the manufacturer's data sets it; the public documents give no generic limitAC 1-36, 1-44 b

3Repair

Rules every wood repair follows

The standard. As strong as the original and equivalent in rigidity and aerodynamic shape; the manufacturer's specifications whenever they exist (AC 43.13-1B par. 1-36). Inspect the internal structure next to any skin damage and repair frame members first (par. 1-47).

Major repairs. Spars, spar flanges, wing main ribs and compression members, three or more adjacent ribs, and plywood stressed covering over 6 in in any direction (14 CFR 43 App. A (b)(1)(iv), (v), (x), (xxii), (xxv)). Replacing a spar is a major repair; new spars come from the manufacturer or a PMA holder, or are made from a manufacturer-approved drawing or a verified original (AC 1-41).

Control surfaces. No weight added aft of the hinge line; stiffness, weight distribution and mass balance as original; check the balance as the aircraft manual says (AC 1-38). Changes that affect flutter are major alterations (14 CFR 43 App. A (a)(1)(xiii)).

Bond faces. Machined smooth and true, bonded soon after surfacing, free of oil, wax, finish, dope and old adhesive. Never sandpaper a softwood bond face; on plywood or aged faces that cannot be re-machined, a very light 220-grit sanding is allowed. A water drop that will not spread shows a surface that will not bond (AC 1-6, 1-6 a, 1-6 b). Adhesive on both faces (1-7).

Safety. Wear a respirator when machining or sanding old bond joints and finishes: some adhesives contain biocides. Most products are flammable and dope and paint highly so; avoid electric sanders near dope, paint and adhesive. Read each product's safety data sheet (AC 43.13-1B pars. 1-18, 1-19).

Spar splices and spar repairs

PointRuleSource
Where a spar may be splicedAnywhere except under wing attachment, landing gear, engine mount, or lift and interplane strut fittings; those fittings may not overlap the spliceAC 1-40; H, Wing Spar Repairs
Under minor fittings (drag and antidrag wire, compression strut)Acceptable if the plates do not disturb the fitting, pulley or bellcrank brackets; plates on the rear face of the rear spar or front face of the front spar, with longer boltsAC 1-40 a, b
Distance from another splice or a reinforcing plateNot adjacent; at least 3 × the length of the longer spliceAC 1-40
Number of splicesNot more than two in any one sparH, Wing Spar Repairs
Scarf slopeNot steeper than 1 in 15 in a stressed part such as a spar; the slopes in AC Figs. 1-5 to 1-9 are minimum slopesH, scarf joints, Fig. 6-18; AC 1-40
Grain next to the scarfCut along the general grain slope. No deviation steeper than 1 in 15 in an outer eighth of the spar depth; steeper local slope only in the inner quarter of a flangeAC 1-39, Fig. 1-4; H Fig. 6-18
Reinforcement platesRequired on every scarf repair to a spar; spruce or plywood, bonded only, ends feathered 5 : 1AC 1-40, Figs. 1-5 to 1-7; H Fig. 6-23
Insert in the top or bottom of a solid sparInsert of the same species; scarf at the ends of the insert no less than 12 to 1AC Fig. 1-10; H Fig. 6-27
Box spar websSame type of plywood, face grain as the original; never solid wood for a plywood webAC 1-42, Fig. 1-9
Solid spar to laminated, or backAllowed with material of the same high quality; external reinforcements replaced as originalAC 1-43
Bolt holesSized so the bolt or bushing needs light tapping with a wood or rawhide mallet; seal the hole and let it cure before the bolt goes in; bushings slightly shortH, Bolt & Bushing Holes; AC 1-71, 1-2 c(1)
Moisture when bonding a cracked spar's plates6 to 8 % in arid areas, 10 to 12 % elsewhere; seal spar butts with a penetrating, moisture-resistant finishAC 1-44 b, c

Rib repairs

PointRuleSource
Replacement ribFrom the manufacturer or a PMA holder, or made from an approved drawing or a verified original rib; the contour matters for handlingAC 1-46
Cap strip scarf spliceScarf 10 × the cap thickness A; spruce block on the side away from the covering, 16 A long (3 A past each end of the scarf); plywood side plates both sides, same material and thickness as the rib's ownH, Wing Rib Repairs, Fig. 6-15; AC Fig. 1-11
Rib to wood sparNever nail through the cap strips. Adhesive plus cement-coated, barbed or spiral nails through the vertical rib members on each face of the sparAC 1-46 a
Compression ribsMethods of AC Fig. 1-12 (A), (B), (C): cut and replace the cap strips, bonded plywood side plates; on (B) and (C) the plates run the full distance between the sparsAC 1-46 b
Three or more adjacent ribs, or the leading edge between themMAJOR REPAIR14 CFR 43 App. A (b)(1)(xxv)

Spar and rib splices: where, how long, how steep

Three views of wood splices. A solid spar in elevation with red no-splice zones under the wing attach and lift strut fittings and two splices of length L at least 3L apart. A scarf splice in top view and elevation at its true 1 in 15 slope: scarf 15 times the spar depth D, reinforcing plates on both faces with ends feathered 5 to 1. A rib cap strip of thickness A with a 10A scarf, a 16A spruce block reaching 3A past each end on the side away from the covering, and plywood side plates.
Splice locations and the spar scarf after AC 43.13-1B pars. 1-39 and 1-40 (Figs. 1-4 to 1-7) and FAA-H-8083-31B Figs. 6-18 and 6-23; rib cap strip after FAA-H-8083-31B Fig. 6-15 and AC Fig. 1-11. Slopes are drawn true. The aircraft's manual governs.

Plywood skin patches: which one, and its limits

PatchUse whenKey dimensions, in (mm)Source
Fabric (doped on)Hole up to 1 in (25) after trimming; not within 1 in (25) of a frame member; not on a leading edge or the fuselage frontEdges of the hole sealed; patch overlaps the skin 1 in (25) min, pinked edgesAC 1-52; H, Fabric Patch
Splayed (flush, tapered)Hole up to 15 T, skin not over 1/10 in (2.5)Taper 5 T (5 : 1); 1/10 in skin: hole 1-1/2 in (38) max, repair circle 2-1/2 in (64)AC 1-51 a; H, Splayed Patch
Surface (overlay)Between or along framing members, entirely aft of the 10 % chord line or wrapped round the leading edge to end aft of it. The Handbook limits it to skins not over 1/8 in (3.2)Perimeter up to 50 in (1,270), one frame or rib space; corner radius 5 T min; forward edge bevel 4 T; fabric over it lapping 2 in (51); H: doublers 1/4 in (6.4) minAC 1-51 b; H, Surface Patch
Scarf (the preferred repair)Radius of curvature over 100 T at every point of the trimmed openingSlope 1 in 12 at the steepest; backing-block method for damage up to 25 T across and 15 T or more from a framing memberAC 1-51 c, Figs. 1-15, 1-16; H, Scarf Patch
Plug, round or ovalSkin damage only, structure underneath soundRound: hole radius 2 in (51) or 3 in (76); doubler radius 2-5/8 and 1-3/8 in (67 and 35), or 3-7/8 and 2-1/8 in (98 and 54). Oval: 7 × 5 in (178 × 127) max. Doubler 1/4 in (6.4) soft plywood, preformed when the rise exceeds 1/8 in in 6 in (3.2 in 152); No. 4 round-head screwsAC 1-51 d, Figs. 1-17, 1-18; H, Plug Patch

T = skin thickness. Face grain of every patch as the original skin. A patch on plywood stressed covering over 6 in (152 mm) is a major repair (14 CFR 43 App. A (b)(1)(xxii)). The AC's other figure dimensions (scarf patch backing, gussets) are in Figs. 1-15 and 1-16.

Splayed and scarf patches in section

Two sections through a plywood skin. A splayed patch in a .100 in skin drawn to true proportions: hole 1.50 in diameter maximum, taper 5T each side, repair circle 2.50 in diameter maximum. A scarf patch at a true 1 in 12 slope, 12T each side, bonded over a backing block: damage up to 25T across and at least 15T from the rib.
Patch geometry after AC 43.13-1B par. 1-51 a and c (Fig. 1-15) and FAA-H-8083-31B (splayed and scarf patches). T is the skin thickness; the face grain of a patch runs as the original skin.

Surface and plug patches in plan

Plan of a surface patch within one rib space, aft of the 10 percent chord line: perimeter up to 50 in, corner radius 5T minimum, forward edge beveled 4T, fabric over it lapping 2 in. Plan of a round plug patch over a doubler ring with hole radius R1 and doubler radii R2 and R3, and a table: hole radius 2.00 in with doubler radii 2.625 and 1.375 in, or 3.00 in with 3.875 and 2.125 in.
Surface patch after AC 43.13-1B par. 1-51 b; plug patch sizes after par. 1-51 d and Figs. 1-17 and 1-18. A patch on stressed plywood covering over 6 in is a major repair (14 CFR 43 App. A).

Minimum bend radius for aircraft plywood

ThicknessPliesCold mandrel, 90° to face grain, in (mm)Cold, 0° or 45°Soaked in hot water, 90°Soaked, 0° or 45°
.035 in (0.9)32 (51)1.1 (28)0.5 (13)0.1 (2.5)
.070 in (1.8)35.2 (132)3.2 (81)1.5 (38)0.4 (10)
.100 in (2.5)38.6 (218)5.2 (132)2.6 (66)0.8 (20)
.125 in (3.2)312 (305)7.1 (180)3.8 (97)1.2 (30)
.155 in (3.9)316 (406)10 (254)5.3 (135)1.8 (46)
.185 in (4.7)320 (508)13 (330)7.1 (180)2.6 (66)
.160 in (4.1)517 (432)11 (279)6 (152)2 (51)
.190 in (4.8)521 (533)14 (356)7 (178)3 (76)
.225 in (5.7)527 (686)17 (432)10 (254)4 (102)
.250 in (6.3)531 (787)20 (508)12 (305)5 (127)
.315 in (8.0)543 (1,092)28 (711)16 (406)7 (178)
.375 in (9.5)554 (1,372)36 (914)21 (533)10 (254)

AC 43.13-1B Table 1-2: cold columns at 10 % moisture content; soaked columns thoroughly soaked in hot water, then bent on cold mandrels. Dry the part on the form; a heated form may reach 300 °F (149 °C) (AC 1-49). Double curvature needs molded plywood of the right shape (AC 1-50); a sheet of heavy paper that wrinkles on the surface shows double curvature (AC 1-48).

Step by step: a bonded wood repair

StepActionWhat to do
1Get the dataThe manufacturer's repair data first; AC 43.13-1B chapter 1 where none exists. Check whether the repair is major (14 CFR 43 App. A).
2Dry and inspectMoisture meter, tap, probe and look; dry the structure before judging bonds (AC 1-29).
3Cut back to sound woodRemove all decay and damage; lay out the scarf or patch with the slopes and sizes in the tables above.
4Prepare the facesMachine smooth and true; vacuum; no sandpaper on softwood bond faces; keep sealer off the bond areas plus 1/4 in (6.4 mm) (AC 1-6, 1-66 d).
5Mix and spreadWithin pot life; adhesive on both faces; never thin a batch to extend its life (AC 1-7, 1-8).
6ClampPressure per the adhesive, evenly, with blocks at least twice the thinner member; nail strips at 1 in (25 mm) pitch. Check squeeze-out along the whole joint and wipe the excess (AC 1-10, 1-11).
7Test a sampleA joint from the same batch and the repair's scraps, broken after cure: wood failure on both faces (AC 1-29 h).
8Finish and recordSeal, varnish and refinish; drain holes as original; logbook entry, and FAA Form 337 for a major repair.

Finishing and protection

SurfaceFinishSource
Acceptable finishesVarnish to Fed. Spec. TT-V-109, or a coating approved by the airframe manufacturer or the FAA; STC exterior systems made under PMA; low-viscosity epoxy as an inside finish where bonding followsAC 1-65
Interior members, inside of skins, box sparsOne thinned coat, then two full coats; wheel wells and hull bottoms: an extra coat of aluminised sealer, 12 to 16 oz of aluminum paste per gallon (90 to 120 g/L)AC 1-67
End grain (spar butts, skin edges, holes, scarfed faces)One thinned coat, then 2 to 4 full coats to a smooth gloss; under dope or lacquer, a dope-proof sealer or epoxyAC 1-69
Bond areasKeep sealer off them plus 1/4 in (6.4 mm) each side; seal the margins after cure, or use an approved epoxy coating with a compatible epoxy adhesiveAC 1-66 d, e
Plywood under fabric or tape (dope system)Dope-proof one-part varnish or two-part epoxy varnish, two clear dope coats, a third with pinked airplane cloth laid in it, then brush and spray coatsAC 1-70, 2-6 g
Bolt holesVarnish or sealer into the hole, fully cured before the boltAC 1-71; H
ColorA dark aircraft in the sun can reach 185 °F (85 °C) inside; wood loses about 25 % of its strength at 125 °F (52 °C). White or light colors run coolestAC 1-68
Before finishingRemove adhesive squeeze-out, oil (naphtha), wax crayon marks, sawdust and chips from closed baysAC 1-66 a to c

Worked example: a hole in 1/10 in plywood skin

Wing skin T = 0.100 in (2.5 mm), damage trimmed round to 2 in (51 mm), radius of curvature 20 in (508 mm), back of the skin reachable. A made-up case to show the AC 43.13-1B par. 1-51 arithmetic.

  1. Fabric patch? Only up to 1 in (25 mm): no (par. 1-52).
  2. Splayed patch? Largest hole 15 T = 15 × 0.100 = 1.5 in (38 mm): the 2 in hole is too big (par. 1-51 a).
  3. Scarf patch: curvature check 100 T = 10 in (254 mm); 20 in is above it, so a scarf patch may be installed (par. 1-51 c).
  4. Scarf width at 1 in 12: 12 T = 1.2 in (30 mm) each side; outside diameter of the scarf 2 + 2 × 1.2 = 4.4 in (112 mm).
  5. Backing-block method (Fig. 1-15, section D-D): damage up to 25 T = 2.5 in (64 mm) across and at least 15 T = 1.5 in (38 mm) from a framing member. The 2 in hole qualifies if its edge is 1.5 in or more from the frame.
  6. Paperwork: 2 in is under the 6 in (152 mm) of 14 CFR 43 App. A (b)(1)(xxii), so the skin damage alone does not make it a major repair.

A scarf patch, 4.4 in (112 mm) across at 1 in 12, on a backing block if the hole is 1.5 in (38 mm) clear of framing; face grain as the skin.

Cross-check against other documents

PointDocumentWhat it saysReading
Moisture at inspectionAC 1-29 g; H, Inspection of Wood StructuresAC: 8 to 16 %, preferably 10 to 12 %. H: ideal 8 to 12 %. Both: over 20 % means fungusAgree on 20 %; aim for 10 to 12 %.
Moisture before bondingAC 1-44 b; H, GluesAC: 6 to 8 % in arid areas, 10 to 12 % elsewhere. H: 8 to 12 %, equal in both partsMatch the climate the aircraft lives in; both parts the same.
Clamping pressureAC 1-10 b; H, Glues, Fig. 6-12AC (resorcinol, typical): 125 to 150 psi softwood, 150 to 200 psi hardwood. H: 10 to 150 psi softwood by glue viscosity, up to 200 psi hardwood; example 100 to 250 psi at 75 °FDiffer: the adhesive maker's sheet governs, as both say.
Scarf slope in a sparH, scarf joints, Figs. 6-18, 6-24; AC 1-40H: not steeper than 15 to 1 in a stressed part; Fig. 6-24 shows 10 to 1 in solid wood. AC: the figure slopes are minimum slopesUse the flatter of the manufacturer's slope and 1 in 15 on a spar.
Scarf patch on a curved skinAC 1-51 c; H, Scarf PatchAC: radius over 100 T at all points. H prints «not greater than 100 times»The H wording is reversed; the AC governs: a flatter skin takes a scarf patch.
Surface patch skin thicknessAC 1-51 b; H, Surface PatchAC gives no thickness limit; H: skins not over 1/8 inApply the 1/8 in limit (stricter).
Splices in one sparAC 1-40; H, Wing Spar RepairsAC: spacing 3 × the longer splice. H: not more than two splicesBoth apply.
Test joint acceptanceAC 1-29 h; H, Testing Glued JointsAC: wood fibers on both faces is the ideal. H: at least 75 % wood fiber over the fractureUse 75 % as the figure.
Size of a skin repair and paperworkAC 1-51 b; 14 CFR 43 App. A (b)(1)(xxii)AC allows a surface patch up to 50 in perimeter. The rule: plywood stressed covering over 6 in in any direction is a major repairA large AC patch is still a major repair: Form 337.
Compression woodAC Table 1-1 note 2i; ANC-19 sec. 2.306AC: high specific gravity, excessive summerwood, low color contrast. ANC-19: lower side of leaning trees, wide rings, opaque summerwood in thin sectionAgree: reject it; in doubt, toughness test.
Syllabus EASA Part-66 Appendix I (as amended by Regulation (EU) 2023/989): 6.3.2 Wooden structures. FAA-S-ACS-1: AM.II.B Non-Metallic Structures.

Quick check

Plywood skin 0.100 in thick, hole trimmed round to 1-3/4 in, clear of framing, radius of curvature 20 in. Which patch does AC 43.13-1B par. 1-51 allow?

  1. A splayed patch

    Not this one. No: a splayed patch takes holes up to 15 T = 1.5 in.

  2. A scarf patch at 1 in 12

    Best fit. Yes: the radius is over 100 T = 10 in, and the scarf patch is the preferred skin repair.

  3. A doped fabric patch

    Not this one. No: fabric patches are for holes up to 1 in.

On a real job, the SRM decides.

Questions people actually ask

Can I replace spruce with Douglas fir?

Yes, in the same or slightly reduced sizes if the reduction is substantiated. It is hard to work with hand tools and splits; avoid large solid pieces, which are hard to inspect (AC 43.13-1B Table 1-1). Use the original species whenever possible (par. 1-2 b).

Is epoxy acceptable instead of resorcinol?

Only if it meets par. 1-4 a (aircraft manual, Mil Spec, AMS or TSO) and is compatible with the structure. Many epoxies lack durability with heat or moisture; never change the mix ratio to alter cure time (par. 1-4 b(6)).

Can I bond over old casein glue?

Scrape off every trace first: residual alkalinity can stop the new adhesive curing (par. 1-4 b(1)).

How do I find a compression failure?

Shine a light at a low angle along the grain on the compression face: waviness in the grain is the sign. A borescope through inspection holes, or new holes on the aft face of the front spar and fore face of the rear spar, lets you see the face and top of the spar (par. 1-29 f(2)(m); FAA-H-8083-31B ch. 6).

When is a wood repair a major repair?

Spars, spar flanges, wing main ribs and compression members, three or more adjacent ribs, and plywood stressed covering over 6 in in any direction (14 CFR 43 App. A (b)(1)). Spar replacement is a major repair (par. 1-41).

Why seal end grain so heavily?

End grain absorbs far more moisture than side grain: one thinned coat and two to four full coats (par. 1-69). Spar butts in dry climates check and split without it (par. 1-44 c).

Limits of this guide

What the sources support, and no further.

  • The manufacturer's data governs spar, rib and skin repairs, splice locations and crack limits when it exists (AC 43.13-1B par. 1-36).
  • No generic damage limit is published: any decay is repaired or replaced; crack and damage sizes that may remain are the manufacturer's.
  • Figure dimensions of AC Figs. 1-5 to 1-12, 1-15 and 1-16 (plate lengths, gussets, backing strips) are not reproduced: read the figure.
  • Adhesive times, temperatures and pressures come from the adhesive maker's data.
  • Not covered: wood propellers, and the design of new wood structure.

Where to buy

AmericaDistributor coming soon
EuropeDistributor coming soon
OceaniaDistributor coming soon

Are you a distributor? Get listed →

Distributors coming soon.

Main sources

  • AC 43.13-1B with Change 1, Acceptable Methods, Techniques, and Practices: Aircraft Inspection and Repair — Chapter 1: par. 1-2 and Table 1-1 (species, defects); pars. 1-3 to 1-11 (plywood, adhesives, bonding); pars. 1-18, 1-19 (safety); pars. 1-28, 1-29 (deterioration, inspection); pars. 1-36 to 1-52 with Figs. 1-2 to 1-18 and Table 1-2 (repairs); pars. 1-64 to 1-71 (finishing). Chapter 2: par. 2-6 g (plywood under fabric).
  • FAA-H-8083-31B, Aviation Maintenance Technician Handbook: Airframe, Volume 1, Chapter 6, Aircraft Wood and Structural Repair — Inspection of Wood Structures, Fig. 6-6 and 6-8; Suitable Wood, Defects and Fig. 6-10; Glues and Fig. 6-12; Testing Glued Joints; Wing Rib Repairs, Figs. 6-15, 6-18; Wing Spar Repairs, Figs. 6-23, 6-24, 6-27; Bolt & Bushing Holes; Plywood Skin Repairs (fabric, splayed, surface, plug and scarf patches).
  • ANC-19, Wood Aircraft Inspection and Fabrication, Army-Navy-Civil Committee (20 December 1943) — Secs. 2.302 (slope of grain, scribe and ink), 2.303 (checks, shakes, splits) and 2.306 (compression wood).
  • 14 CFR Part 43, Appendix A, Major Alterations, Major Repairs, and Preventive Maintenance — (a)(1)(xiii); (b)(1)(iv), (v), (x), (xxii) and (xxv).

Cross-checked with other manuals and standards in our library.

Educational reference only. Not approved data. Always consult the applicable SRM, AMM, or AC 43.13-1B and your certifying authority.