Testing of Materials: Hardness, Conductivity, Tensile, Fatigue and Impact

Two tests are run in the shop: hardness (Rockwell, Brinell) and, on aluminum, electrical conductivity; together they verify a heat treatment, but neither names the alloy. Tensile, fatigue and impact are laboratory tests to an ASTM method, and acceptance always comes from the material specification. This guide gives the rules the public documents print for each and where the limits come from.

View PDF

1Identification

Where to buy

The tests at a glance

TestWhat it measuresWhereSource
Rockwell hardnessDepth of indentation: a minor load seats a steel ball or a diamond cone, then the major load is applied. Superficial Rockwell, with light loads, for thin sections and small partsShop or labAC 43.13-1B par. 4-17
Brinell hardnessLoad divided by the area of the impression left by a 10 mm ballLab, or a part that will not return to serviceAC 43.13-1B par. 4-18
Vickers, Knoop (micro)Diamond pyramid; microhardness with loads up to 1 kgLab: plating, foil, wire, case depth, decarburizationAC 43.13-1B pars. 4-19, 4-20
Electrical conductivityConductivity in %IACS (percent of the International Annealed Copper Standard) by eddy current; with hardness it verifies aluminum heat treatmentShop or labMIL-STD-1537C foreword, par. 1.1
TensileStress-strain curve: modulus, yield at 0.2 % offset, ultimate, elongation, reduction of areaLabMIL-HDBK-5J par. 1.4.4
FatigueCycles to failure at a stress (or strain) amplitude and ratio R, plotted as S-N curvesLabMIL-HDBK-5J par. 1.4.9
ImpactEnergy absorbed in breaking a notched barLabASTM E23

Stress is reported in ksi (1 ksi = 1,000 psi = 6.895 MPa).

Before testing: knowing what the metal is

CheckWhat it showsSource
Material knownA hardness test verifies heat treatment only if the material type is knownAC 43.13-1B par. 4-16
MagnetStrongly attracted: iron, nickel, cobalt or their alloys; lightly: cold-worked stainless or Monel; not attracted: aluminum, magnesium, copper alloys, annealed 300-series stainless. Never the final basis for identificationAC 43.13-1B par. 4-22
Clad aluminumThree distinct layers on the edge under a magnifying glassAC 43.13-1B par. 4-23a
10 % caustic soda (sodium hydroxide)2014, 2017 and 2024 turn black (copper); clad sheet blackens only at the edge. No blackening does not prove a non-heat-treatable alloy: 6053, 6061 and 7075 stay brightAC 43.13-1B par. 4-23b
Eye protection with caustic liquidsEye or face protection where liquid chemicals, acids or caustic liquids can reach the eyes29 CFR 1910.133(a)(1)
CompositionAlloys that do not blacken are identified only by chemical or spectro-analysisAC 43.13-1B par. 4-23b

Test standards by number

StandardTitle, as citedCited by
ASTM E8Tension Testing of Metallic MaterialsMIL-HDBK-5J ref. 1.4.4
ASTM E10Brinell Hardness of Metallic MaterialsAC 43.13-1B par. 4-18c; MIL-STD-1537C par. 2.2
ASTM E18Rockwell Hardness and Rockwell Superficial Hardness of Metallic MaterialsAC 43.13-1B par. 4-17; MIL-STD-1537C par. 2.2
ASTM E23Notched Bar Impact Testing of Metallic Materials—
ASTM E466Constant Amplitude Axial Fatigue Tests of Metallic MaterialsMIL-HDBK-5J ref. 1.4.9(a)
ASTM E606Constant-Amplitude Low-Cycle Fatigue TestingMIL-HDBK-5J ref. 1.4.9(b)
ASTM B193Electrical Resistivity of Conductor MaterialsMIL-STD-1537C par. 4.2.1
MIL-STD-1537CElectrical Conductivity Test for Verification of Heat Treatment of Aluminum Alloys, Eddy Current Method—
SAE AMS 2658Hardness and Conductivity Inspection of Wrought Aluminum Alloy Parts—

Titles as the citing document gives them; current editions may word them differently.

2Allowable damage

Hardness testing: the rules in print

ItemRuleSource
UsesVerify heat treatment; find loss of strength after fire or abusive heating; find understrength bolts in stock by testing across the hex flatsAC 43.13-1B par. 4-16
Where not to testIt leaves a pit: not on sealing surfaces, fatigue-critical parts or load-bearing areas that return to serviceAC 43.13-1B par. 4-16
SteelGives the tensile strength within reasonable limits; not suitable for very soft or very hard steelAC 43.13-1B par. 4-16
AluminumTells annealed, cold-worked, heat-treated and heat-treated-and-aged material apart; of little value for strength or quality of heat treatmentAC 43.13-1B pars. 4-16, 4-23
ReadingsSeveral readings, averaged; thickness and edge distance considered so the metal does not distortAC 43.13-1B par. 4-16
SurfaceRemove case-hardened, corroded, pitted or decarburized metal deep enough, without cold-working the steel underneathAC 43.13-1B par. 4-16
Brinell on a curveNo indentation on a radius under 1 in (25.4 mm)AC 43.13-1B par. 4-18a(1)
Brinell loadApplied steadily, perpendicular to the surface within 2°; no bulge or mark on the far side; impression clearly outlinedAC 43.13-1B par. 4-18a(3) to (6)
Brinell range15 HB with the 500 kg load to 627 HB with the 3,000 kg loadAC 43.13-1B par. 4-18b(3)
Heat damageHardness or conductivity tests on the affected metal, to TO 33B-1-1TO 1-1A-1 par. 2.1.4

Typical Brinell hardness of aluminum alloys

AlloyO (annealed)Hardened temper, HB
110023H18: 44
300328H16: 47
201445T6: 135
202447T4: 120
2025—T6: 110
505247H36: 73
606130T4: 65 · T6: 95
6151—T6: 100
7075—T6: 135
7079—T6: 135
Castings—195-T6: 75 · 220-T4: 75 · C355-T6: 80 · A356-T6: 70

Brinell number, 500 kg load, 10 mm ball: AC 43.13-1B Table 4-5 (reference MIL-H-6088G). Typical values, not acceptance limits: the material or heat-treat specification sets those.

Conductivity check of aluminum heat treatment

ItemRequirementMIL-STD-1537C
InstrumentDirect reading wherever possible; an indirect one needs at least three certified standards within ±10 %IACS of the value, one above and one below4.1.1
Sensitivity, accuracy0.5 %IACS clearly distinguishable; ±1.0 %IACS or better through non-conductive coatings at least 0.003 in (0.076 mm) thick4.1.2, 4.1.3
Instrument standardsAt least two, certified to ±0.85 %IACS, at least 10 %IACS apart: one in 25 to 32, one in 38 to 62 %IACS4.2.2
StandardizeWarm-up about 20 min (solid state 5 min); every 15 min in continuous use4.3.1, 4.3.1.1
Lift-off0.003 in (0.076 mm) shim on a bare standard: difference not over 0.5 %IACS, or the instrument goes back to calibration4.3.1.2
CalibrationEvery 120 days or on objective evidence; never over 12 months4.3.2
SurfaceClean; 150 RHR (165 RMS) maximum; a non-conductive coating up to 0.003 in (0.076 mm) needs no lift-off correction4.4.1
EdgesMinimum edge distance by the user's tests or the instrument maker's specification4.4.2
TemperatureProbe, standards and part within 3 °C (5.4 °F) of each other5.1.2
Hardness firstHardness of the first part of the lot, to ASTM E10 or E185.1.1
Doubtful readingRecheck the standards, then test hardness before any disposition5.1.2
Clad and AlcladClad only with documented correlation; Alclad at 50 to 75 kHz, and over 0.091 in (2.3 mm) the cladding is spot-faced off one part per lot for a correction factor4.4.4, 4.4.5
Thin partsDown to 40 % under the minimum thickness: three stacked specimens. Correction over 2.5 %IACS: test stacked; over 5 %IACS: use a higher frequency4.4.3.1
Acceptance range—5.2: the materials specification for the alloy and temper
What it provesAcceptable hardness or conductivity does not guarantee mechanical properties: evidence of the specified heat treatment is needed as well5.1.2.1
PersonnelIndirect-reading instruments: level II to NAS 4104.5.2

Two hardness conditions can give the same conductivity: both values define a temper (par. 6.1). Figure 2 (7075, hardness against conductivity) is for information only, never for acceptance.

Conductivity check and the stress-strain curve

An eddy-current probe on a bare standard with a .003 in lift-off shim and on three stacked thin specimens, with the MIL-STD-1537C rules. A stress-strain curve with the modulus E, the .002 in/in offset line giving Fty, the maximum stress Ftu, fracture and the elongation e.
Conductivity after MIL-STD-1537C pars. 4.2 to 5.2; tensile terms after MIL-HDBK-5J pars. 1.4.3 and 1.4.4. Acceptance values come from the materials specification.

3Repair

Running the hardness tests

TestIndenter and loadUse and calibrationSource
RockwellHardened steel ball or diamond cone; standard minor load, then standard major loadMost common for ferrous and many non-ferrous metals; superficial scales for thin or small parts. Tester calibrated to ASTM E18AC 43.13-1B par. 4-17
Brinell10 mm (0.394 in) ball; 500 kg (4.90 kN) for copper and aluminum alloys, 3,000 kg (29.4 kN) for steel and cast ironLarge impression: the part should not be used after testing. Tester calibrated to ASTM E10AC 43.13-1B par. 4-18
Vickers136° square-based diamond pyramid; 1 to 120 kg, standard loads 5, 10, 20, 30, 50, 100 and 120 kg, most testing at 50 kg or lessHV = load ÷ area of the impressionAC 43.13-1B par. 4-19
MicrohardnessKnoop or Vickers, up to 1 kg (1,000 g), mostly 100 to 500 gSmall or thin parts, foil, wire, case depth, single microconstituents, edges (grinding burn, decarburization), platingAC 43.13-1B par. 4-20

Rockwell, Brinell and Vickers in section

Three hardness tests in section: a Rockwell indenter under minor then major load with the depth that gives the reading, a Brinell ball of .394 in (10 mm) leaving an impression d under load P, and the Vickers 136 degree diamond pyramid. The Brinell formula with a worked reading of 100 HB, and boxes for where testing is not allowed and what to check.
Indenters, loads and rules after AC 43.13-1B pars. 4-16 to 4-20 and Table 4-5. Hardness alone does not prove the temper.

Step by step: verifying the heat treatment of an aluminum part

StepActionWhat to do
1Know the alloy and temperFrom the marking, the certificate or the drawing. Take the acceptance range for that alloy and temper from its materials specification (MIL-STD-1537C par. 5.2).
2Prepare the surfaceClean, 150 RHR maximum; paint or film up to 0.003 in (0.076 mm) may stay (par. 4.4.1). Alclad: 50 to 75 kHz, and the spot-face correction on thicker parts (par. 4.4.5).
3Standardize the instrumentWarm it up, standardize on the two instrument standards that bracket the range and check lift-off with a 0.003 in shim (pars. 4.3.1, 4.3.1.2).
4Measure hardness firstOn the first part of the lot, to ASTM E10 or E18 (par. 5.1.1), away from sealing surfaces, fatigue-critical and load-bearing areas if the part returns to service (AC 43.13-1B par. 4-16).
5Read conductivityProbe pressed firmly, probe, standards and part within 3 °C (5.4 °F), clear of edges (pars. 4.4.2, 5.1.2). Thin stock: stack as par. 4.4.3.1.
6DispositionIn range with the right hardness: accept, with the heat-treat evidence (par. 5.1.2.1). Out of range or doubtful: recheck the standards, then hardness, then decide; rework or replacement follows the SRM.
7RecordInstrument, standards, readings, hardness and result on the work order.

Worked example: thin 7075-T6, stacked conductivity

The example of MIL-STD-1537C par. 4.4.3.1e and f: a lot of bare 0.040 in (1.02 mm) 7075-T6 sheet, tested with a 60 kHz instrument. The standard assumes an acceptance range of 30.0 to 34.5 %IACS for the example; the real one comes from the materials specification.

  1. At 60 kHz and 32 %IACS the minimum thickness is 0.050 in (1.27 mm) (figure 1), and 0.6 of it is 0.030 in (0.76 mm). The 0.040 in sheet lies between, so three specimens are first tested stacked to find a thickness correction.
  2. Stacked readings 34.0 and 34.5 %IACS and a third in the same range: all within 30.0 to 34.5 %IACS.
  3. Average unstacked minus average stacked: +2 %IACS, within the 2.5 %IACS that allows unstacked testing.
  4. Corrected range for the rest of the lot, unstacked: 30.0 + 2 to 34.5 + 2 = 32.0 to 36.5 %IACS.

Worked example: reading a Brinell impression

A 500 kg load on the 10 mm ball leaves an impression 2.50 mm across (0.098 in).

  1. HB = P ÷ [(πD ÷ 2) × (D − √(D² − d²))], P in kg, D and d in mm (AC 43.13-1B par. 4-18).
  2. √(10² − 2.50²) = √93.75 = 9.682 mm; D − 9.682 = 0.318 mm.
  3. πD ÷ 2 = 15.708 mm; area = 15.708 × 0.3175 = 4.988 mm².
  4. HB = 500 ÷ 4.988 = 100.

Tensile, fatigue and impact: what the laboratory reports

PropertyDefinition in printSource
Tensile ultimate (Ftu)The maximum stress reached, on the original cross-section (engineering stress); in ksi (× 6.895 = MPa)MIL-HDBK-5J par. 1.4.4.4
Tensile yield (Fty)Stress at 0.002 in/in (0.2 %) plastic strain offsetMIL-HDBK-5J par. 1.4.4.3
Elongation (e)Permanent increase in gage length after fracture, in % of the original: 2 in (50.8 mm) gage on rectangular, 4D on round specimens, unless the material specification says otherwiseMIL-HDBK-5J par. 1.4.4.5
Reduction of area (RA)Loss of cross-section at the fracture, in % of the original; less affected by test variables than elongationMIL-HDBK-5J par. 1.4.4.6
Test speedDesign data come from coupons tested up to 0.01 in/in/min, the standard maximum static rate of ASTM E8MIL-HDBK-5J par. 1.4.3.3
FatigueAxial tests, fully reversed or at a mean stress; R = minimum ÷ maximum stress or strain; S-N curves per R. Load control to ASTM E466, strain control to ASTM E606MIL-HDBK-5J par. 1.4.9
ImpactEnergy to break a notched bar, at the temperature the specification sets. 17-4PH, large bar in H900 and H925, may have very low impact strength below zeroASTM E23; MIL-HDBK-5J par. 2.6.9.0
Acceptance—The material specification's minimums; design allowables in MIL-HDBK-5J
Syllabus EASA Part-66 Appendix I (as amended by Regulation (EU) 2023/989): 6.1(b) Testing of ferrous materials; 6.2(b) Testing of non-ferrous materials. FAA-S-ACS-1: AM.I.E Aircraft Materials, Hardware, and Processes.

Quick check

Two 7075 parts give the same conductivity reading. What tells their heat-treat conditions apart?

  1. Their hardness

    Best fit. Yes: two hardness conditions can give the same %IACS; both values define a temper (MIL-STD-1537C par. 6.1, figure 2).

  2. A second reading at a higher frequency

    Not this one. No: frequency deals with thickness (par. 4.4.3.1), not temper.

  3. A magnet

    Not this one. No: aluminum is not attracted, and the magnet test is never a final basis (AC 43.13-1B par. 4-22).

On a real job, the SRM decides.

Questions people actually ask

Can a part go back into service after a hardness test?

Only if the pit is acceptable where it is: AC 43.13-1B par. 4-16 keeps hardness tests off sealing surfaces, fatigue-critical parts and load-bearing areas that return to service, and a Brinell-tested piece should not be used afterwards (par. 4-18b(2)).

Does a good conductivity reading prove the heat treatment?

No. MIL-STD-1537C par. 5.1.2.1: acceptable hardness or conductivity does not guarantee the mechanical properties; the heat-treat evidence is needed too, and the acceptance range comes from the materials specification (par. 5.2).

Is there a hardness to tensile strength conversion?

For steel, AC 43.13-1B par. 4-16 says hardness gives tensile strength within reasonable limits, not for very soft or very hard steel. For aluminum it is of little value (par. 4-23). Conversion tables are not reproduced here: no public document used gives one.

Which test after a fire or an overheat?

Hardness or conductivity on the affected metal, to TO 33B-1-1 (TO 1-1A-1 par. 2.1.4); Rockwell, Brinell and Vickers testers help find loss of strength after fire or abusive heating (AC 43.13-1B par. 4-16). The SRM gives the limits.

Why are fatigue and impact not shop tests?

They break specimens under controlled loading: axial fatigue at set stress ratios (MIL-HDBK-5J par. 1.4.9, ASTM E466 and E606) and notched-bar impact (ASTM E23). In service, fatigue shows as cracks from repeated loads (TO 1-1A-1 par. 3.11.1), found by inspection.

Limits — when NOT to use this

What the sources support, and no further.

  • The specification governs. Acceptance of any test comes from the material or heat-treat specification and the aircraft's SRM.
  • No conductivity ranges by alloy and temper: MIL-STD-1537C gives the method, the materials specification the range.
  • No hardness conversion table: none is printed in the public documents used.
  • Table 4-5 values are typical, not limits.

Where to buy

AmericaDistributor coming soon
EuropeDistributor coming soon
OceaniaDistributor coming soon

Are you a distributor? Get listed →

Distributors coming soon.

Main sources

  • AC 43.13-1B CHG 1, Acceptable Methods, Techniques, and Practices: Aircraft Inspection and Repair — Chapter 4, section 2, testing of metals: pars. 4-16 to 4-23; Table 4-5 (hardness values for aluminum alloys, reference MIL-H-6088G).
  • MIL-STD-1537C, Electrical Conductivity Test for Verification of Heat Treatment of Aluminum Alloys, Eddy Current Method (25 Jun 2002) — Foreword par. 2; pars. 1.1, 2.2, 4.1.1 to 4.1.3, 4.2.1, 4.2.2, 4.3.1 to 4.3.2, 4.4.1 to 4.4.5, 4.5.2, 5.1.1 to 5.2, 6.1; figures 1 and 2.
  • MIL-HDBK-5J, Metallic Materials and Elements for Aerospace Vehicle Structures (31 Jan 2003) — Pars. 1.4.3.3, 1.4.3.4, 1.4.4, 1.4.4.3 to 1.4.4.6, 1.4.9 and references; 2.6.9.0 (17-4PH).
  • TO 1-1A-1 / NAVAIR 01-1A-1, General Manual for Structural Repair (15 Jan 2016) — Par. 2.1.4 (heat damage); 3.11.1 (metal fatigue).
  • 29 CFR 1910.133, Eye and face protection — Par. (a)(1).
  • Test standards named by number — ASTM E8, E10, E18, E23, E466, E606, B193; SAE AMS 2658; NAS 410: named as what governs; not reproduced.

Cross-checked with other manuals and standards in our library.

Educational reference only. Not approved data. Always consult the applicable SRM, AMM, or AC 43.13-1B and your certifying authority.