MS14155 at a glance
Where to buy
Specification
| Item | Value |
|---|---|
| Type | Washer, recessed, countersunk both sides |
| Material | For bolts and nuts up to and including 180 ksi |
| Status | Check the current issue before design use. |
Dimensions by size
| Dimension, in | 1/4 | 5/16 | 3/8 | 7/16 | 1/2 |
|---|---|---|---|---|---|
| B — B | .500 | .615 | .761 | .873 | .999 |
| B tolerance | ± .005 | ± .005 | ± .005 | ± .005 | ± .005 |
| D — D | .253 | .316 | .378 | .441 | .503 |
| D tolerance | ± .002 | ± .002 | ± .002 | ± .002 | ± .002 |
| ID — I.D. | .342 | .404 | .499 | .561 | .624 |
| V — V | .119 | .119 | .151 | .151 | .156 |
Dimensions as listed. Blank cells (shown as a dash): not stated in the documents we hold; take them from the standard.
Part numbers
| Part no. | Size | B, in (± .005) | D, in (± .002) | I.D., in (± .005) | V, in (± .005 to ± .007) |
|---|---|---|---|---|---|
| MS14155-4 | 1/4 | .500 | .253 | .342 | .119 |
| MS14155-5 | 5/16 | .615 | .316 | .404 | .119 |
| MS14155-6 | 3/8 | .761 | .378 | .499 | .151 |
| MS14155-7 | 7/16 | .873 | .441 | .561 | .151 |
| MS14155-8 | 1/2 | .999 | .503 | .624 | .156 |
Part numbers commonly stocked. The standard governs and may list others.
Part number
What each code means
| Part | Meaning |
|---|---|
| Example | MS14155-4 — 1/4 nominal size |
Notes from the standard
- Tolerances as listed: B ± .005, D ± .002, I.D. ± .005; V ± .005 on -4 and -5, ± .007 on -6, -7 and -8.
- The listing shows a 45° countersink on both faces (± 1°) and a V dimension; the letters follow the listing, check them against the standard.
Where to buy
AmericaDistributor coming soonOur partner for this region is on its way
EuropeDistributor coming soonOur partner for this region is on its way
OceaniaDistributor coming soonOur partner for this region is on its way
Distributors coming soon.
Sources
- MS14155 — Washer, Recessed, Countersunk on Both Surfaces, for Wheel Bolts and Nuts — nominal sizes and part numbers.
Educational reference only. not approved data. Always consult the applicable SRM, AMM, or AC 43.13-1B and your certifying authority.