Specification
Where to buy| Item | Value |
|---|---|
| Type | Pneumatic-hydraulic installation tool |
| Maker | Gage Bilt |
| Air pressure | 90-100 psi |
| Setting stroke | 0.540 in (13.72 mm) |
| Rated pull load | 3,300 lb (14.68 kN) |
| Hand held weight | 4.30 lb (1.95 kg) |
| Item | Value |
|---|---|
| Air consumption | 3.9 CFM at 20 cycles a minute |
| Hydraulic fluid | Automatic transmission fluid, Dexron III or equivalent |
| Noise level | 81.5 dB(A) |
| Vibration | Tested, no hazards found |
| Air inlet | 1/4-18 female pipe thread |
Part numbers
| Part no. | Size | Item |
|---|---|---|
| GB704 | Tool | Installation tool, nose assembly not included |
Gage Bilt's part number for this tool.
Nose assembly selection chart
| Fastener | Diameter | Straight | Right angle | Offset |
|---|---|---|---|---|
| CherryMAX, CherryMAX 'AB', NAS1919U, NAS1921U, MIL-R-7885, NAS9301-9312, BACR15FR/FP, BACR15GF/GK | 1/8, 5/32, 3/16 | 456MAX-701-17, 456MAX-749-35 | 456MAX-753A-54 | 456MAX-704-43OS |
| Nut plate rivets: MS20600 series, CCR244/264/274, MS/9SP/PT, BACR15CC/CF/DA/DR | 3/32 | 3C-704-56 | 3C-704-54RA | 3C-715-40OS |
| Nut plate rivets | 1/8 | 4C-704-56 | 4C-704-54RA | 4C-715-40OS |
| Nut plate rivets | 5/32 | 5C-704-56 | 5C-704-54RA | 5C-715-40OS |
| Nut plate rivets | 3/16 | 6C-704-56 | 6C-704-54RA | 6C-715-40OS |
| 'A' code: NAS1398A, NAS1399A | 3/32 | 3A-704-56 | 3A-704-54RA | 3A-715-40OS |
| 'A' code | 1/8 | 4A-704-56 | 4A-704-54RA | 4A-715-40OS |
| 'A' code | 5/32 | 5A-704-56 | 5A-704-54RA | 5A-715-40OS |
| 'A' code | 3/16 | 6A-704-56 | 6A-704-54RA | 6A-715-40OS |
| Ground stud: M83454, BACS53B1EA1/2 | 8/32 | GS8-704-56 | GS8-704-54RA | GS8-715-40OS |
| Ground stud | 10/32 | — | GS10-704-54RA | GS10-715A-40OS |
456MAX assemblies install 1/8, 5/32 and 3/16 in. 456MAX-749-35 is a front end ejecting nose assembly. 715 series nose assemblies require the 704001 adapter. Right angle nose assemblies may require more than one pull. The last two digits give the length the nose extends from the tool: -20 = 2.0 in.
Notes from the maker
- Air pressure is not to exceed 100 psi, except where noted.
- It is recommended the tool be operated 50 out of every 60 minutes, where prolonged use is expected.
- Hearing protection is required: the level measured in a simulated work environment was 81.5 dB(A).
- Ensure the nose assembly and tip are properly matched for the fastener being installed.
Where to buy
AmericaDistributor coming soonOur partner for this region is on its way
EuropeDistributor coming soonOur partner for this region is on its way
OceaniaDistributor coming soonOur partner for this region is on its way
Distributors coming soon.
Sources
- Gage Bilt, GB704 installation manual, 6/11 Rev. 8/11 — Specifications (p. 2), selection chart (p. 11).
Educational reference only. not approved data. Always consult the applicable SRM, AMM, or AC 43.13-1B and your certifying authority.