NAS1578 at a glance
Where to buy
Specification
| Item | Value |
|---|---|
| Type | Flat pan head bolt |
| Material | A: alloy steel; C: A-286 corrosion-resistant steel |
| Status | Check the current issue before design use. |
Part numbers
Part numbers commonly stocked, with grip and length. The standard governs and may list others.
Dia. 322 part numbers
| Part no. | Grip, in | Length, in |
|---|---|---|
| NAS1578A3T2 | .125 | .487 |
| NAS1578C3T2 | .125 | .487 |
| NAS1578A3T3 | .187 | .549 |
| NAS1578C3T3 | .187 | .549 |
| NAS1578A3T4 | .250 | .613 |
| NAS1578C3T4 | .250 | .613 |
| NAS1578A3T5 | .312 | .675 |
| NAS1578C3T5 | .312 | .675 |
| NAS1578A3T6 | .375 | .738 |
| NAS1578C3T6 | .375 | .738 |
| NAS1578A3T7 | .438 | .801 |
| NAS1578C3T7 | .438 | .801 |
| NAS1578A3T8 | .500 | .863 |
| NAS1578C3T8 | .500 | .863 |
| NAS1578A3T9 | .562 | .925 |
| NAS1578C3T9 | .562 | .925 |
| NAS1578A3T10 | .625 | .988 |
| NAS1578C3T10 | .625 | .988 |
| NAS1578A3T11 | .688 | 1.051 |
| NAS1578C3T11 | .688 | 1.051 |
| NAS1578A3T12 | .750 | 1.113 |
| NAS1578C3T12 | .750 | 1.113 |
Part number
What each code means
| Part | Meaning |
|---|---|
| A | Material: Alloy steel |
| C | Material: A-286 corrosion-resistant steel |
| P | Material: Suffix P: cadmium plating, Type II Class 2 |
| Example | NAS1578A3T2 — Flat pan head bolt, grip .125, length .487 |
Notes from the standard
- Grip tolerance ±.010.
- Offset cruciform recess per MS14191.
- The P listing code is plating, not a different bolt.
- Part number format as commonly written; check the standard for the exact format.
- Approved data governs. Use the bolt the SRM, drawing or IPC calls for.
Where to buy
AmericaDistributor coming soonOur partner for this region is on its way
EuropeDistributor coming soonOur partner for this region is on its way
OceaniaDistributor coming soonOur partner for this region is on its way
Distributors coming soon.
Sources
- NAS1578 — Bolt, Flat Pan Head, Offset Cruciform Recess — nominal sizes and part numbers.
Educational reference only. not approved data. Always consult the applicable SRM, AMM, or AC 43.13-1B and your certifying authority.